Milan Technology MIL-SM2401MAF User Manual Page 63

  • Download
  • Add to my manuals
  • Print
  • Page
    / 178
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 62
55
portleg
[enable |
disable]
[ports]
POE mode
Enabling or disabling
per port legacy
detection.
Switch(poe)#
portleg enable
3-6
portpri
[critical | high
| low] [ports]
POE mode
Set port priority for the
power supply
management.
Switch(poe)#
portpri critical 2
portplm
[value] [ports]
POE mode
Set per port power l
imit
Max.
Switch(poe)#
portplm 12200
5-7
System log Commands Set
Commands
Command
Level
Description Defaults
Example
show
systemlog
User EXEC Display system log.
Switch>
show systemlog
show
systemlog
Privileged
EXEC
Show system log client
& server information
switch# show
systemlog
Syslog Client:
Enable
Syslog Server Ip:
192.168.16.2
systemlog ip
[IP address]
Global
configuration
mode
Set System log server
IP address.
Switch(config)#
systemlog ip
192.168.1.100
systemlog
[enable |
disable]
Global
configuration
mode
Enable or disable
system log mode
Switch(config)#
systemlog
enable
Page view 62