Fault status detect
Null: no PD present
Overload: current support over 475mA @ DC 48V and
over 50 milliseconds
DR fail: PD discovery resistor is not in the limited range
Parametric
information
It will show current PD parameters, it include
Discover-resistor detected value, current, voltage, power
consumption, classification current and determined class
Port configuration
control
Port Disable / Enable.
PD detect control (enable/disable), Classification detect
control (enable/disable), DC disconnect detect control
Mode status
System detects status, it will show I –sample, V-sample
and R-detect.
NTP
Supports RFC 2030 Simple Network Time Protocol
(option)
SMTP
Supports RFC2821 Simple Mail Transfer protocol
(option)
System Log System Log record up to 1000 entries
Power monitor
Support power supply monitoring function for AC power,
DC power, fan status
3 types of power supply can be installed with POE switch,
POW-DPW, POE-SPW, and POE-UPW.
Power testing Support test function to testing power supply